plasma igg responses Search Results


91
Sino Biological plasma igg responses
a NT 50 values for COVID-19 convalescent <t>plasma</t> (CE) and CoronaVac vaccinee plasma (I) using D614G mutant pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test ( **P < 0.01). b Plasma <t>anti-IgG</t> ELISA reactivity to S(ECD), RBD, and NTD. Normalized area under the curve (AUC) values are plotted. Black dots stand for CoronaVac vaccinees, and red dots stand for convalescents. c Comparison of anti-IgG ELISA AUC values among RBD.V2 (triangle), D614G (circle), and 242–244Δ (diamond) mutants of S1. White stands for CoronaVac vaccinees, and red stands for convalescents. Statistical significance was determined using paired one-tailed t -test ( ***P < 0.001). d NT 50 fold-change from D614G to 501Y.V2 for convalescent and CoronaVac vaccinee plasma by pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test (n.s., no significance). e NT 50 fold-change from WT to 501Y.V2 for convalescent and CoronaVac vaccinee plasma by authentic virus neutralization assay. Statistical significance was determined using one-tailed t -test (n.s., no significance). f Comparison of NT 50 values by pseudovirus or authentic virus neutralization assay between WT/D614G and the indicated mutants for CoronaVac vaccinee plasma samples. g Comparison of NT 50 values by pseudovirus or authentic virus neutralization assay between WT/D614G and the indicated mutants for CE samples. h Summary of the fold change of NT 50 for the indicated mutants from D614G. Color gradient indicates fold change values ranging from +1 (white) to −6.7 (blue). All plotted values and horizontal bars in this figure indicate the geometric mean.
Plasma Igg Responses, supplied by Sino Biological, used in various techniques. Bioz Stars score: 91/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/plasma+igg+responses/SARS-CoV-2+Total+IgG+Antibody+Titer+Assay+Kit/pmc08138844-219-0-16
Average 91 stars, based on 1 article reviews
plasma igg responses - by Bioz Stars, 2026-11
91/100 stars
  Buy from Supplier

96
Vector Laboratories vectastain elite abc kit
a NT 50 values for COVID-19 convalescent <t>plasma</t> (CE) and CoronaVac vaccinee plasma (I) using D614G mutant pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test ( **P < 0.01). b Plasma <t>anti-IgG</t> ELISA reactivity to S(ECD), RBD, and NTD. Normalized area under the curve (AUC) values are plotted. Black dots stand for CoronaVac vaccinees, and red dots stand for convalescents. c Comparison of anti-IgG ELISA AUC values among RBD.V2 (triangle), D614G (circle), and 242–244Δ (diamond) mutants of S1. White stands for CoronaVac vaccinees, and red stands for convalescents. Statistical significance was determined using paired one-tailed t -test ( ***P < 0.001). d NT 50 fold-change from D614G to 501Y.V2 for convalescent and CoronaVac vaccinee plasma by pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test (n.s., no significance). e NT 50 fold-change from WT to 501Y.V2 for convalescent and CoronaVac vaccinee plasma by authentic virus neutralization assay. Statistical significance was determined using one-tailed t -test (n.s., no significance). f Comparison of NT 50 values by pseudovirus or authentic virus neutralization assay between WT/D614G and the indicated mutants for CoronaVac vaccinee plasma samples. g Comparison of NT 50 values by pseudovirus or authentic virus neutralization assay between WT/D614G and the indicated mutants for CE samples. h Summary of the fold change of NT 50 for the indicated mutants from D614G. Color gradient indicates fold change values ranging from +1 (white) to −6.7 (blue). All plotted values and horizontal bars in this figure indicate the geometric mean.
Vectastain Elite Abc Kit, supplied by Vector Laboratories, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/plasma+igg+responses/VECTASTAIN+Elite+ABC+Universal+PLUS+Kit%2C+Peroxidase+(Horse+Anti-Mouse%2FRabbit+IgG)/pm18596671-59-8-12
Average 96 stars, based on 1 article reviews
vectastain elite abc kit - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

94
Vector Laboratories rat igg antibody
a NT 50 values for COVID-19 convalescent <t>plasma</t> (CE) and CoronaVac vaccinee plasma (I) using D614G mutant pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test ( **P < 0.01). b Plasma <t>anti-IgG</t> ELISA reactivity to S(ECD), RBD, and NTD. Normalized area under the curve (AUC) values are plotted. Black dots stand for CoronaVac vaccinees, and red dots stand for convalescents. c Comparison of anti-IgG ELISA AUC values among RBD.V2 (triangle), D614G (circle), and 242–244Δ (diamond) mutants of S1. White stands for CoronaVac vaccinees, and red stands for convalescents. Statistical significance was determined using paired one-tailed t -test ( ***P < 0.001). d NT 50 fold-change from D614G to 501Y.V2 for convalescent and CoronaVac vaccinee plasma by pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test (n.s., no significance). e NT 50 fold-change from WT to 501Y.V2 for convalescent and CoronaVac vaccinee plasma by authentic virus neutralization assay. Statistical significance was determined using one-tailed t -test (n.s., no significance). f Comparison of NT 50 values by pseudovirus or authentic virus neutralization assay between WT/D614G and the indicated mutants for CoronaVac vaccinee plasma samples. g Comparison of NT 50 values by pseudovirus or authentic virus neutralization assay between WT/D614G and the indicated mutants for CE samples. h Summary of the fold change of NT 50 for the indicated mutants from D614G. Color gradient indicates fold change values ranging from +1 (white) to −6.7 (blue). All plotted values and horizontal bars in this figure indicate the geometric mean.
Rat Igg Antibody, supplied by Vector Laboratories, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/plasma+igg+responses/Rat+IgG+(Control+Antibody)/pm12631119-74-3-6
Average 94 stars, based on 1 article reviews
rat igg antibody - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

96
Vector Laboratories immpress horseradish peroxidase goat anti rabbit igg polymer detection kit peroxidase
a NT 50 values for COVID-19 convalescent <t>plasma</t> (CE) and CoronaVac vaccinee plasma (I) using D614G mutant pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test ( **P < 0.01). b Plasma <t>anti-IgG</t> ELISA reactivity to S(ECD), RBD, and NTD. Normalized area under the curve (AUC) values are plotted. Black dots stand for CoronaVac vaccinees, and red dots stand for convalescents. c Comparison of anti-IgG ELISA AUC values among RBD.V2 (triangle), D614G (circle), and 242–244Δ (diamond) mutants of S1. White stands for CoronaVac vaccinees, and red stands for convalescents. Statistical significance was determined using paired one-tailed t -test ( ***P < 0.001). d NT 50 fold-change from D614G to 501Y.V2 for convalescent and CoronaVac vaccinee plasma by pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test (n.s., no significance). e NT 50 fold-change from WT to 501Y.V2 for convalescent and CoronaVac vaccinee plasma by authentic virus neutralization assay. Statistical significance was determined using one-tailed t -test (n.s., no significance). f Comparison of NT 50 values by pseudovirus or authentic virus neutralization assay between WT/D614G and the indicated mutants for CoronaVac vaccinee plasma samples. g Comparison of NT 50 values by pseudovirus or authentic virus neutralization assay between WT/D614G and the indicated mutants for CE samples. h Summary of the fold change of NT 50 for the indicated mutants from D614G. Color gradient indicates fold change values ranging from +1 (white) to −6.7 (blue). All plotted values and horizontal bars in this figure indicate the geometric mean.
Immpress Horseradish Peroxidase Goat Anti Rabbit Igg Polymer Detection Kit Peroxidase, supplied by Vector Laboratories, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/plasma+igg+responses/ImmPRESS+HRP+Anti-Rabbit+IgG+(Peroxidase)+Polymer+Detection+Kit%2C+made+in+Goat/pmc12516197-110-7-18
Average 96 stars, based on 1 article reviews
immpress horseradish peroxidase goat anti rabbit igg polymer detection kit peroxidase - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

90
BTNX Inc rapid response covid-19 igg/igm test cassette (whole blood/serum/plasma)
Immunological tests available globally for detection of COVID-19.
Rapid Response Covid 19 Igg/Igm Test Cassette (Whole Blood/Serum/Plasma), supplied by BTNX Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/plasma+igg+responses/rapid+responsetm+covid+19+test+cassette+kit+1/pmc07690661-50-2-27
Average 90 stars, based on 1 article reviews
rapid response covid-19 igg/igm test cassette (whole blood/serum/plasma) - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

N/A
Anti-RAT-IgG (H&L) (RABBIT) Antibody Fluorescein Conjugated - 612-4202
  Buy from Supplier

Image Search Results


a NT 50 values for COVID-19 convalescent plasma (CE) and CoronaVac vaccinee plasma (I) using D614G mutant pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test ( **P < 0.01). b Plasma anti-IgG ELISA reactivity to S(ECD), RBD, and NTD. Normalized area under the curve (AUC) values are plotted. Black dots stand for CoronaVac vaccinees, and red dots stand for convalescents. c Comparison of anti-IgG ELISA AUC values among RBD.V2 (triangle), D614G (circle), and 242–244Δ (diamond) mutants of S1. White stands for CoronaVac vaccinees, and red stands for convalescents. Statistical significance was determined using paired one-tailed t -test ( ***P < 0.001). d NT 50 fold-change from D614G to 501Y.V2 for convalescent and CoronaVac vaccinee plasma by pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test (n.s., no significance). e NT 50 fold-change from WT to 501Y.V2 for convalescent and CoronaVac vaccinee plasma by authentic virus neutralization assay. Statistical significance was determined using one-tailed t -test (n.s., no significance). f Comparison of NT 50 values by pseudovirus or authentic virus neutralization assay between WT/D614G and the indicated mutants for CoronaVac vaccinee plasma samples. g Comparison of NT 50 values by pseudovirus or authentic virus neutralization assay between WT/D614G and the indicated mutants for CE samples. h Summary of the fold change of NT 50 for the indicated mutants from D614G. Color gradient indicates fold change values ranging from +1 (white) to −6.7 (blue). All plotted values and horizontal bars in this figure indicate the geometric mean.

Journal: Cell Research

Article Title: Humoral immune response to circulating SARS-CoV-2 variants elicited by inactivated and RBD-subunit vaccines

doi: 10.1038/s41422-021-00514-9

Figure Lengend Snippet: a NT 50 values for COVID-19 convalescent plasma (CE) and CoronaVac vaccinee plasma (I) using D614G mutant pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test ( **P < 0.01). b Plasma anti-IgG ELISA reactivity to S(ECD), RBD, and NTD. Normalized area under the curve (AUC) values are plotted. Black dots stand for CoronaVac vaccinees, and red dots stand for convalescents. c Comparison of anti-IgG ELISA AUC values among RBD.V2 (triangle), D614G (circle), and 242–244Δ (diamond) mutants of S1. White stands for CoronaVac vaccinees, and red stands for convalescents. Statistical significance was determined using paired one-tailed t -test ( ***P < 0.001). d NT 50 fold-change from D614G to 501Y.V2 for convalescent and CoronaVac vaccinee plasma by pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test (n.s., no significance). e NT 50 fold-change from WT to 501Y.V2 for convalescent and CoronaVac vaccinee plasma by authentic virus neutralization assay. Statistical significance was determined using one-tailed t -test (n.s., no significance). f Comparison of NT 50 values by pseudovirus or authentic virus neutralization assay between WT/D614G and the indicated mutants for CoronaVac vaccinee plasma samples. g Comparison of NT 50 values by pseudovirus or authentic virus neutralization assay between WT/D614G and the indicated mutants for CE samples. h Summary of the fold change of NT 50 for the indicated mutants from D614G. Color gradient indicates fold change values ranging from +1 (white) to −6.7 (blue). All plotted values and horizontal bars in this figure indicate the geometric mean.

Article Snippet: Plasma IgG responses to SARS-CoV-2 S (SARS-CoV-2 Spike S1 + S2 ECD Antibody Titer Assay Kit, Sino Biological Inc., KIT 004), RBD (SARS-CoV-2 Spike RBD Antibody Titer Assay Kit, Sino Biological Inc., KIT 002), NTD (SARS-CoV-2 Spike S1 NTD-His & AVI Recombinant Protein, Sino Biological Inc., 0591-V49H), S1-D614G (SARS-CoV-2 Spike S1(D614G)-His Recombinant Protein, Sino Biological Inc., 40591-V08H3), S1-RBD.V2 (SARS-CoV-2 Spike S1(K417N, E484K, N501Y, D614G)-His Recombinant Protein, Sino Biological Inc., 40591-V08H10), S1–501Y.V2 NTD (SARS-CoV-2 Spike S1(242–244Δ, D614G)-His, Sino Biological Inc., BD61–2) were measured by ELISA.

Techniques: Clinical Proteomics, Mutagenesis, Neutralization, One-tailed Test, Enzyme-linked Immunosorbent Assay, Comparison, Virus

a NT 50 values for ZF2001 vaccinee plasma/sera using D614G mutant pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test (* P < 0.05; n.s., no significance). b Plasma/serum anti-IgG ELISA reactivity to S(ECD), RBD, and NTD. Normalized AUC values are plotted. Black circles stand for R1–R10, and red circles stand for R11–R20. c Comparison of anti-IgG ELISA AUC values among RBD.V2 (triangle), D614G (circle), and 242–244Δ (diamond) mutants of S1. White stands for R1–R10, and red stands for R11–R20. Statistical significance was determined using paired one-tailed t -test (*** P < 0.001; n.s., no significance). d NT 50 fold-change from D614G to 501Y.V2 for ZF2001 vaccinee plasma/sera by pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test (* P < 0.05; ** P < 0.01; *** P < 0.001). e NT 50 fold-change from WT to 501Y.V2 for ZF2001 vaccinee plasma/sera by authentic virus neutralization assay. Statistical significance was determined using one-tailed t -test (* P < 0.05; n.s., no significance). f Comparison of NT 50 values by pseudovirus or authentic virus neutralization assay between WT/D614G and the indicated mutants for ZF2001 vaccinee plasma samples. g Summary of the fold change of NT 50 for the indicated mutants from D614G. Color gradient indicates fold change values ranging from +1 (white) to −6.1 (blue). All plotted values and horizontal bars in this figure indicate the geometric mean. h Pie charts indicating the distribution of antibody sequences from two ZF2001 vaccinees. The number in the inner circle indicates the number of single cells analyzed. Slice size is proportional to the number of clonal enrichment frequencies. The color of the slice indicates neutralization potency toward pseudovirus mutants. Gray, expressed antibodies but with low or no neutralization (IC 50 > 1 μg/mL) and darker gray indicates lower potency; red, high neutralization potency (IC 50 < 1 μg/mL) and darker red indicates higher potency; white, not expressed.

Journal: Cell Research

Article Title: Humoral immune response to circulating SARS-CoV-2 variants elicited by inactivated and RBD-subunit vaccines

doi: 10.1038/s41422-021-00514-9

Figure Lengend Snippet: a NT 50 values for ZF2001 vaccinee plasma/sera using D614G mutant pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test (* P < 0.05; n.s., no significance). b Plasma/serum anti-IgG ELISA reactivity to S(ECD), RBD, and NTD. Normalized AUC values are plotted. Black circles stand for R1–R10, and red circles stand for R11–R20. c Comparison of anti-IgG ELISA AUC values among RBD.V2 (triangle), D614G (circle), and 242–244Δ (diamond) mutants of S1. White stands for R1–R10, and red stands for R11–R20. Statistical significance was determined using paired one-tailed t -test (*** P < 0.001; n.s., no significance). d NT 50 fold-change from D614G to 501Y.V2 for ZF2001 vaccinee plasma/sera by pseudovirus neutralization assay. Statistical significance was determined using one-tailed t -test (* P < 0.05; ** P < 0.01; *** P < 0.001). e NT 50 fold-change from WT to 501Y.V2 for ZF2001 vaccinee plasma/sera by authentic virus neutralization assay. Statistical significance was determined using one-tailed t -test (* P < 0.05; n.s., no significance). f Comparison of NT 50 values by pseudovirus or authentic virus neutralization assay between WT/D614G and the indicated mutants for ZF2001 vaccinee plasma samples. g Summary of the fold change of NT 50 for the indicated mutants from D614G. Color gradient indicates fold change values ranging from +1 (white) to −6.1 (blue). All plotted values and horizontal bars in this figure indicate the geometric mean. h Pie charts indicating the distribution of antibody sequences from two ZF2001 vaccinees. The number in the inner circle indicates the number of single cells analyzed. Slice size is proportional to the number of clonal enrichment frequencies. The color of the slice indicates neutralization potency toward pseudovirus mutants. Gray, expressed antibodies but with low or no neutralization (IC 50 > 1 μg/mL) and darker gray indicates lower potency; red, high neutralization potency (IC 50 < 1 μg/mL) and darker red indicates higher potency; white, not expressed.

Article Snippet: Plasma IgG responses to SARS-CoV-2 S (SARS-CoV-2 Spike S1 + S2 ECD Antibody Titer Assay Kit, Sino Biological Inc., KIT 004), RBD (SARS-CoV-2 Spike RBD Antibody Titer Assay Kit, Sino Biological Inc., KIT 002), NTD (SARS-CoV-2 Spike S1 NTD-His & AVI Recombinant Protein, Sino Biological Inc., 0591-V49H), S1-D614G (SARS-CoV-2 Spike S1(D614G)-His Recombinant Protein, Sino Biological Inc., 40591-V08H3), S1-RBD.V2 (SARS-CoV-2 Spike S1(K417N, E484K, N501Y, D614G)-His Recombinant Protein, Sino Biological Inc., 40591-V08H10), S1–501Y.V2 NTD (SARS-CoV-2 Spike S1(242–244Δ, D614G)-His, Sino Biological Inc., BD61–2) were measured by ELISA.

Techniques: Clinical Proteomics, Mutagenesis, Neutralization, One-tailed Test, Enzyme-linked Immunosorbent Assay, Comparison, Virus

Immunological tests available globally for detection of COVID-19.

Journal: Diagnostics

Article Title: Nucleic Acid and Immunological Diagnostics for SARS-CoV-2: Processes, Platforms and Pitfalls

doi: 10.3390/diagnostics10110866

Figure Lengend Snippet: Immunological tests available globally for detection of COVID-19.

Article Snippet: 6 , Rapid Response COVID-19 IgG/IgM Test Cassette (whole blood/serum/plasma) , gold conjugate , Not provided , IgM/IgG , NA , NA , RUO , Visual , BTNX, Inc..

Techniques: Enzyme-linked Immunosorbent Assay, Indirect ELISA, Magnetic Beads, Luminex, Fluorescence, Surround Optical-fiber Immunoassay, Virus, Diagnostic Assay, Microarray